  ?30mm - twtd series 660 twtd series full size nema pushbuttons twtd series: heavy duty switches built to last key features: ? variety of button sizes up to 2 9/16 (65mm) ? rugged construction includes chrome plated zinc locking ring die cast zinc mounting threads, screw mounted contact blocks ? led or incandescent illumination ? transformer or full voltage ? transparent contact windows ? slow make, double break self-cleaning contacts ? modular construction for maximum fexibility ? double nickel plated terminal screws ? available assembled or as sub-components ? type 4x and ip65 watertight/oiltight panel ? large m3.5 screw terminals with captive sems plate the rugged series of twtd switches offers both variety and durability in an attractive design. with button sizes up to 2 9/16 (65mm), chrome plated zinc locking rings, die cast zinc mounting threads, steel anti-rotation rings, and self cleaning contacts, the twtds are here to stay. the twtd series also offers either led or incandescent illumination in full volt- age and transformer models. transparent contact windows allow the viewing of idecs self cleaning slow- make/slow-break contacts. regardless of your switching needs, the twtd series provides the kind of long lasting, industrial strength quality youve come to expect from idec. ul listed file no. e68961 file no. lr21451 ref no. 117617mc certifcate no. 2005010305145658 switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
661 ?30mm - twtd series specifcations conforming to standards en60947-1, en60947-5-1, vde0660-200, ul508, csa c22-2 no.14 approvals csa: pushbuttons and selector switches: a600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbut - tons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480v) ul: pushbuttons and selector switches: a600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480v) tv: pushbuttons and selector switches: a600=p600 (no, nc)/q600 (no-em, nc-lb) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480v) operating temperature operation: C25 to +50c (without freezing) storage: C40 to +70c (without freezing) vibration resistance 10 to 55hz, 98m/sec 2 (10g) conforming to iec6068-2-6 shock resistance 980m/sec 2 (100g) conforming to iec6068-2-7 electric shock protection class 0 conforming to iec60536 degree of protection ip65 (from front of the panel) (conforming to iec60529) ip54 (key switches) type 1, 2, 3, 3r, 3s, 4, 4x, 5, 12, 13 (conforming to nema ics6-110) mechanical life momentary pushbuttons: 5,000,000 (900 operations per hour) all other switches: 500,000 pollution degree (conforming to iec60947-1) 3 for switches not using a transformer 2 for switches using a transformer mechanical-electrical specifcations rated operational characteristics ac-15: a600 or ue = 250v, le = 3a (no, nc, no-em, nc-lb) dc-13: p600 or ue = 125v, le = 1.1a (no, nc) dc-13: q600 or ue = 125v, le = 0.9a (no-em, nc-lb) rated insulation voltage 600v rated switching overvoltage less than 4kv, conforming to iec60947-1 rated impulse withstanding voltage 4kv for contact circuit 2.5kv for lamp circuit rated thermal current 10 amp minimum switching capacity 5 ma at 3v ac/dc contact operation slow break nc or no, self-cleaning operating force flush and extended pushbuttonswith 1no or 1nc contact: 6.22n (momentary), 7.02n (maintained) additional contacts1no or 1nc: +3.2n (momentary), + 3.3n (maintained) terminal referencing conforming to cenelec en50005 recommended terminal torque 0.8 n m (7.1 in lb.) external short-circuit protection 10a 250v fuse conforming to iec60269-1 applicable wire size minimum 1 x 22 awg, max. 2 x 14 awg or 1 x 12 awg contact resistance initial contact resistance of 50m or less contact gap 4mm (no and nc) 2mm (no-em and nc-lb) lamp ratings incandescent: 1 w leds: 6v: 17ma, 12v: 11ma, 24v: 11ma, / 120, 240v: 10ma maximum inrush current 40 a (40 msec) contact material silver contact ratings contact ratings by utilization category iec 60947-5-1 ac-15 (a600) dc-13 (p600) contact ratings by utilization category operational voltage 24v 48v 50v 110v 220v 440v operation current ac 50/60 hz ac-12 control of resistive loads & solid state loads 10a 10a 10a 6a 2a ac-15 control of electromagnetic loads (> 72va) 10a 7a 5a 3a 1a dc dc-12 control of resistive loads & solid state loads 8a 5a 2.2a 1.1a dc-13 control of electromagnets 5a 2a 1.1a 0.6a switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 662 non-illuminated pushbuttons (assembled) assembled pushbuttons a b ( ) d 1 10 n C r function b: momentary o: maintained v: pushlock t urn reset y: push-pull bezel shape blank: octagonal f: full shroud g: mushroom shroud p: neoprene boot series designation d: twtd series button color b: black g: green w : white r: red s: blue y : y ellow contact arrangement 10: 1no 01: 1nc 20: 2no 02: 2nc 11: 1no-1nc 22: 2no-2nc button shape 1: flush 2: extended 3: mushroom ? 40mm 4: jumbo mushroom ? 65mm 1. use only when interpreting part numbers. do not use for developing part numbers. 2. custom contact confgurations available, contact idec for details. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
663 ?30mm - twtd series non-illuminated pushbuttons (assembled) non-illuminated pushbuttons style contacts momentary maintained flush 1no 1nc 1no-1nc 2no 2nc abd110n-j abd101n-j abd111n-j abd120n-j abd102n-j aod110n-j aod101n-j aod111n-j aod120n-j aod102n-j extended 1no 1nc 1no-1nc 2no 2nc abd210n-j abd201n-j abd211n-j abd220n-j abd202n-j aod210n-j aod201n-j aod211n-j aod220n-j aod202n-j extended with neoprene boot ? 1no 1nc 1no-1nc 2no 2nc abpd210n-j abpd201n-j abpd211n-j abpd220n-j abpd202n-j aopd210n-j aopd201n-j aopd211n-j aopd220n-j aopd202n-j recessed 1no 1nc 1no-1nc 2no 2nc abfd110n-j abfd101n-j abfd111n-j abfd120n-j abfd102n-j aofd110n-j aofd101n-j aofd111n-j aofd120n-j aofd102n-j extended with full shroud 1no 1nc 1no-1nc 2no 2nc abfd210n-j abfd201n-j abfd211n-j abfd220n-j abfd202n-j aofd210n-j aofd201n-j aofd211n-j aofd220n-j aofd202n-j ? 40mm mushroom head 1no 1nc 1no-1nc 2no 2nc abd310n-j abd301n-j abd311n-j abd320n-j abd302n-j aod310n-j aod301n-j aod311n-j aod320n-j aod302n-j ? 40mm mushroom head with full shroud 1no 1nc 1no-1nc 2no 2nc abgd310n-j abgd301n-j abgd311n-j abgd320n-j abgd302n-j aogd310n-j aogd301n-j aogd311n-j aogd320n-j aogd302n-j ? 65mm jumbo mushroom head 1no 1nc 1no-1nc 2no 2nc abd410n-j abd401n-j abd411n-j abd420n-j abd402n-j aod410n-j aod401n-j aod411n-j aod420n-j aod402n-j ? 65mm jumbo mushroom head with shallow shroud 1no 1nc 1no-1nc 2no 2nc abgd410n-j abgd401n-j abgd411n-j abgd420n-j abgd402n-j aogd410n-j aogd401n-j aogd411n-j aogd420n-j aogd402n-j ? 65mm jumbo mushroom head with deep shroud 1no 1nc 1no-1nc 2no 2nc abfd410n-j abfd401n-j abfd411n-j abfd420n-j abfd402n-j aofd410n-j aofd401n-j aofd411n-j aofd420n-j aofd402n-j 1. in place of j, specify the button color code. 2. for sub-assembly part numbers, see next page. 3. for accessories, see page 682. 4. ? neoprene boot available only in black (b), green (g), red (r) and yellow (y). j button color codes color code black b green g red r blue s yellow y white w 1. 65mm jumbo mushroom not available in white. 2. neoprene boot is not available in blue or white. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 664 non-illuminated pushbuttons (sub-assembled) contact block + operator + button = complete part operators style part number momentary maintained flush/extended ABD-100 aod-100 extended with full shroud abfd-200 aofd-200 ? 40mm mushroom/? 65mm jumbo mushroom abd-300 aod-300 ? 40mm mushroom with full shroud abgd-300 aogd-300 ? 65mm jumbo mushroom with shallow shroud abgd-400 aogd-400 ? 65mm jumbo mushroom with deep shroud abfd-400 aofd-400 buttons and lenses style part number flush abd1bn-j extended abd2bn-j ? 40mm mushroom abd3bn-j ? 65mm jumbo mushroom abd4bn-j in place of j, specify the button color code. (see table previous page) contact blocks style part number 1no 1nc all control units bst-010 bst-010s (early make) bst-001 bst-001s (late break) dummy block bst-d 1. dummy blocks (no contacts) are used with an odd number of contact blocks. 2. combining bst -010s and bst-001s result in overlapping contacts (remain on, or closed, when switch is moved between two positions). switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
665 ?30mm - twtd series stop switches (assembled) assembled stop switches a v (l) d 3 (99) 11 (d) n C r C (24v) function v: pushlock turn reset y: push-pull illumination blank: none l: illuminated series designation d: twtd series button/lens size 3: 40mm mushroom illumination circuit 99: full voltage (lamp determines voltage) 126: 120v ac step down transformer 246: 240v ac step down transformer 486: 480v ac step down transformer lamp voltage (full voltage illuminated units only) 6v: 6v ac/dc 12v: 12v ac/dc 24v: 24v ac/dc 120v: 120v ac (led only) 240v: 240v ac (led only) button/lens color code a: amber g: green r: red s: blue w: white y: yellow lamp type (illuminated units only) blank: incandescent d: led contact arrangement 10: 1no 01: 1nc 20: 2no 02: 2nc 11: 1no-1nc 22: 2no-2nc 1. use only when interpreting part numbers. do not use for developing part numbers. 2. custom contact confgurations available, contact idec for details. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 666 stop switches (assembled) stop switches style contacts part number ? 40mm pushlock turn reset non-illuminated 1no 1nc 1no-1nc 2no 2nc avd310n-r* avd301n-r* avd311n-r* avd320n-r* avd302n-r* ? 40mm illuminated pushlock turn reset full voltage 1no-1nc 2no 2nc avld39911 nn-r-l* avld39920 nn-r-l* avld39902 nn-r-l* transformer 1no-1nc 2no 2nc avld3 m 11nn-r* avld3 m 20nn-r* avld3 m 02nn-r* ? 40mm push-pull non-illuminated 1no 1nc 1no-1nc 2no 2nc ayd310n- j ayd301n- j ayd311n- j ayd320n- j ayd302n- j ? 40mm push-pull full voltage 1no-1nc 2no 2nc ayld39911 nn-k-l ** ayld39920 nn-k-l ** ayld39902 nn-k-l ** transformer 1no-1nc 2no 2nc ayld3 m 11nn-k ** ayld3 m 20nn-k ** ayld3 m 02nn-k** ? 40mm momentary push-pull (3-position) full voltage 1no-1nc 1nc-1lb? ayld229911 nn-k-l -tk962 ayld229902s nn-k-l-tk962 transformer 1no-1nc 1nc-1lb? ayld22 m 11nn-k-tk962 ayld22 m 02snn-k-tk962 unibody e-stops style contacts part number ? 40mm pushlock turn reset (available in red only) 1no-1nc 2nc hn1e-bv4f11-r* hn1e-bv4f02-r* illuminated ? 40mm pushlock turn reset (available in red only) 1no-1nc 2nc hn1e-lv4f11q n-r-l hn1e-lv4f02q n-r-l 1. in place of j, specify the button color code 2. in place of k, specify the lens color code. 3. in place of l , specify the full voltage (lamp voltage) code. 4. in place of m, specify the transformer voltage code. 5. in place of n , specify the lamp type code. 6. with single unit construction, the positive action contacts are?integrated in the body of the switch. this provides an extra?degree of safety and reliability for critical emergency stop?functions. 7. hn1e series e-stops comply with the iec e-stop addendum to the low voltage directive, this includes tamper proof operation whereby a change of contact state is not possible by teasing or foating the operator. 8. 3 position push-pull available in spring return to center only. 9. *available in red only. 10. **not available in blue. 11. ? the most common confguration for motor starting applica - tions. 12. for sub-assembly part numbers, see next page. 13. for nameplates and accessories, see page 684 and page 682. 14. for dimensions, see page 687. 3 position push-pull ? contact push center pull nc (bst-001) o o x nc-lb (bst-001s) o x x no (bst-010) x o o no-em (bst-010s) x x o j button color codes color code black b green g red r blue s yellow y k led/lens color codes color code amber a green g red r blue s white w l full voltage codes voltage code 6v ac/dc 6v 12v ac/dc 12v 24v ac/dc 24v 120v ac 120v 240v ac 240v (led only) m transformer voltage codes voltage code 120vac 126 240vac 246 480vac 486 transformers step down to 6v. n lamp type codes lamp code incandescent blank led d switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
667 ?30mm - twtd series stop switches (sub-assembled) transformer* + operator + lamp + button/lens = complete part * not required for full voltage units (full voltage clips used instead). operators style part number ?40mm pushlock turn reset avd-300 illuminated ?40mm pushlock turn reset avld3-0600n ?40mm push-pull ayd-3100 illuminated ? 40mm push-pull 2 pos ayld-0600 3 pos ayld22tk962-0b01 buttons and lenses style part number button for pushlock turn reset stop switches (?40mm, red only) avn3b-r lens for illuminated pushlock turn reset stop switches (?40mm, red only) avln3lu-r button for push-pull stop switches (?40mm) ayd3bn- j lens for illuminated push-pull stop switches (?40mm) 2 pos* ayld3l- k 3 pos ayld2l- k 1. in place of j, specify the button color code. (see table below) 2. in place of k, specify the led color code. 3. *not available in blue. lamps style voltage part number led 6v ac/dc lstd-6k 12v ac/dc lstd-1k 24v ac/dc lstd-2k 120v ac lstd-h2k 240v ac lstd-m4k incandescent 6v ac/dc is-6 12v ac/dc is-12 24v ac/dc is-24 120v ac l-120l 1. in place of k, specify the led color code. 2. the led contains a current-limiting resistor and a protection diode. j button color codes color code black b green g red r blue s yellow y k led color codes color code amber a green g red r blue s white w contact blocks style part number 1no 1nc all control units bst-010 bst-010s (early make) bst-001 bst-001s (late break) dummy block bst-d 1. dummy blocks (no contacts) are used with an odd number of contact blocks. 2. combining bst-010s and bst-001s result in overlapping contacts. full voltage clips primary voltage (50/60hz) part number full voltage clips (2 required for each unit) apd-f transformers style primary voltage (50/60hz) part number 120v ac twd-0126 240v ac twd-0246 480v ac twd-0486 6v secondary voltage (uses 6v lamp). switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 668 pilot lights (assembled) assembled pilot lights a p d 1 126 d n C r C ( ) function p: pilot light series designation d: twtd series lens shape 1: dome rated operational voltage (primary) transformer type 126: 120v ac 246: 240v ac 486: 480v ac full voltage type 99: full voltage lamp voltage (full voltage illuminated units only) 6v : 6v ac/dc 12v : 12v ac/dc 24v : 24v ac/dc 120v : 120v ac (led only) 240v : 240v ac (led only) lens color code a: amber g: green r: red s: blue w: white y: yellow lamp type blank: incandescent d: led use only when interpreting part numbers. do not use for developing part numbers. led and incandescent pilot lights style operating voltage part number led incandescent transformer dome 120v ac 240v ac 480v ac apd1126dn-k apd1246dn-k apd1486dn-k apd1126n-k apd1246n-k apd1486n-k full voltage dome apd199dn-k-l apd199n-k-l 1. in place of k, specify the lens/led color code. 2. in place of l , specify the full voltage code (lamp voltage). 3. yellow pilot light comes with white led. k lens color codes color code amber a green g red r blue s white w yellow y l full voltage codes voltage code 6v ac/dc 6v 12v ac/dc 12v 24v ac/dc 24v 120v ac 120v 240v ac 240v (led only) switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
669 ?30mm - twtd series pilot lights (sub-assembled) transformer* + operator + lamp + lens = complete part * not required for full voltage units (full voltage clips used instead). one each from left column plus one selection from right column operators style part number transformer apd-006 full voltage apd-199 full voltage operator comes with full voltage clips. lenses style part number dome lens apn106ln-k 1. in place of k, specify the lens color code. 2. led and incandescent lenses differ in shade only . some colors have only one shade. lamps style voltage part number led 6v ac/dc lstd-6k 12v ac/dc lstd-1k 24v ac/dc lstd-2k 120v ac lstd-h2k 240v ac lstd-m4k incandescent 6v ac/dc is-6 12v ac/dc is-12 24v ac/dc is-24 120v ac l-120l 1. in place of k, specify the led color code. 2. the led contains a current-limiting resistor and a protection diode. full voltage clips primary voltage (50/60hz) part number apd-f required for all full voltage models. two pieces each. transformers style primary voltage (50/60hz) part number led 120v ac twd-0126 240v ac twd-0246 480v ac twd-0486 6v secondary voltage (use 6v lamp). k led/lens color codes color code amber a green g red r blue s white w yellow y y ellow lens only. yellow led not available, use white led. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 670 illuminated pushbuttons (assembled) assembled illuminated pushbuttons a l ( ) d 2 126 11 (d) n C r C ( ) function l: momentary action ol: maintained action bezel shape blank: octagonal f: full shroud series designation d: twtd series lens shape 2: extended 3: mushroom ? 40mm rated operational voltage (primary) transformer type 126: 120v ac 246: 240v ac 486: 480v ac full voltage type 99: full voltage lamp voltage (full voltage only) 6v : 6v ac/dc 12v : 12v ac/dc 24v : 24v ac/dc 120v: 120v ac 240v : 240v ac (led only) lens color code a: amber g: green r: red s: blue w: white y: yellow lamp type blank: incandescent d: led contact arrangement 20: 2no 02: 2nc 11: 1no-1nc 1. use only when interpreting part numbers. do not use for developing part numbers. 2. all transformers step down to 6v . switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
671 ?30mm - twtd series illuminated pushbuttons (assembled) illuminated pushbuttons style contacts part number momentary maintained extended lens full voltage 1no-1nc 2no 2nc ald29911nn-k-l ald29920nn-k-l ald29902nn-k-l aold29911nn-k-l aold29920nn-k-l aold29902nn-k-l transformer 1no-1nc 2no 2nc ald2 m 11nn-k ald2 m 20nn-k ald2 m 02nn-k aold2 m 11nn-k aold2 m 20nn-k aold2 m 02nn-k extended lens with full shroud full voltage 1no-1nc 2no 2nc alfd29911nn-k-l alfd29920nn-k-l alfd29902nn-k-l aolfd29911nn-k-l aolfd29920nn-k l aolfd29902nn-k-l transformer 1no-1nc 2no 2nc alfd2 m 11nn-k alfd2 m 20nn-k alfd2 m 02nn-k aolfd2 m 11nn-k aolfd2 m 20nn-k aolfd2 m 02nn-k ? 40mm mushroom lens full voltage 1no-1nc 2no 2nc ald39911nn-k-l ald39920nn-k-l ald39902nn-k-l aold39911nn-k-l aold39920nn-k-l aold39902nn-k-l transformer 1no-1nc 2no 2nc ald3 m 11nn-k ald3 m 20nn-k ald3 m 02nn-k aold3 m 11nn-k aold3 m 20nn-k aold3 m 02nn-k 1. in place of k, specify the lens color code. 2. in place of l , specify the full voltage code (lamp voltage). 3. in place of m , specify the transformer voltage code. 4. in place of n , specify the lamp type code. 5. light is independent of switch position. 6. y ellow pushbutton comes with white led only. k lens color codes color code amber a green g red r blue s white w yellow y l full voltage codes voltage code 6v ac/dc 6v 12v ac/dc 12v 24v ac/dc 24v 120v ac 120v 240v ac 240v (led only) m transformer voltage codes voltage code 120vac 126 240vac 246 480vac 486 6v secondary voltage (uses 6v lamp). n lamp type codes lamp code incandescent blank led d switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 672 illuminated pushbuttons (sub-assembled) transformer* + contact block + operator + lamp + lens = complete part *not required for full voltage types (full voltage types use apd-f full voltage clips). operators style part number momentary maintained extended ald-0600 aold-0600 extended with full shroud alfd-0600 aolfd-0600 40mm mushroom ald-0600 aold-0600 lenses style part number extended aln06lu-k ? 40mm mushroom aln3lu-k in place of k, specify the lens color code. full voltage clips style part number full voltage clips (2 required for each unit) apd-f required for all full voltage models. lamps style voltage part number led 6v ac/dc lstd-6k 12v ac/dc lstd-1k 24v ac/dc lstd-2k 120v ac lstd-h2k 240v ac lstd-m4k incandescent 6v ac/dc is-6 12v ac/dc is-12 24v ac/dc is-24 120v ac l-120l 1. in place of k, specify the led color code. 2. the led contains a current-limiting resistor and a protection diode. k led/lens color codes color code amber a green g red r blue s white w yellow y y ellow lens only. yellow led not available, use white led. contact blocks style part number 1no 1nc all control units bst-010 bst-010s (early make) bst-001 bst-001s (late break) dummy block bst-d 1. dummy blocks (no contacts) are used with an odd number of contact blocks. 2. combining bst -010s and bst-001s result in overlapping contacts (remain on, or closed, when switch is moved between two positions). transformers style primary voltage (50/60hz) part number transformers 120v ac twd-0126 240v ac twd-0246 480v ac twd-0486 6v secondary voltage (use 6v lamp). switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
673 ?30mm - twtd series non-illuminated selector switches (assembled) assembled selector switches a s d 2 ( ) ( ) 11 n C ( ) function s: selector switch series designation d: twtd series number of positions 2: 2-position 3: 3-position spring return action blank: maintained 1: spring return from right 2: spring return from left 3: 2-w ay spring return from left and right circuit number (see circuit # column of selector switch contact arrangement chart on beginning on page 679.) contact arrangement code 10: 1no 01: 1nc 20: 2no 02: 2nc 40: 4no 04: 4nc 11: 1no-1nc 22: 2no-2nc operator style code blank: knob operator l: lever operator k: key operator 1. use only when interpreting part numbers. do not use for developing part numbers. 2. custom key removal codes available. please contact idec for details. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 674 non-illuminated selector switches (assembled) non-illuminated 2-position selector switches style part number 1. the truth table indicates the operating position of contact block when the operator is switched to that position. x = on (closed contacts) o = off (open contacts) x x = overlapping contacts: remain on (closed contacts) when switch is moved between these two positions. 2. all knob and lever selector switches come in black. other colors are available by ordering the knob or lever separately . 3. custom contact arrangements available, see page 679. contact mounting operator position maintained spring return from right spring return from left l r l r l r l r 1no 1 2 o o x o knob lever key asd210n asd2l10n asd2k10n asd2110n asd21l10n asd21k10n asd2210n asd22l10n asd22k10n 1nc 1 2 x o o o knob lever key asd201n-116 asd2l01n-116 asd2k01n-116 asd2101n-116 asd21l01n-116 asd21k01n-116 asd2201n-116 asd22l01n-116 asd22k01n-116 1no 1nc 1 2 x o o x knob lever key asd211n asd2l11n asd2k11n asd2111n asd21l11n asd21k11n asd2211n asd22l11n asd22k11n 2no 1 2 o o x x knob lever key asd220n asd2l20n asd2k20n asd2120n asd21l20n asd21k20n asd2220n asd22l20n asd22k20n 2nc 1 2 x x o o knob lever key asd202n-104 asd2l02n-104 asd2k02n-104 asd2102n-104 asd21l02n-104 asd21k02n-104 asd2202n-104 asd22l02n-104 asd22k02n-104 2no 2nc 1 2 3 4 o x o x x o x o knob lever key asd222n asd2l22n asd2k22n asd2122n asd21l22n asd21k22n asd2222n asd22l22n asd22k22n 2no 2nc 1 2 3 4 o o x x x x o o knob lever key asd222n-111 asd2l22n-111 asd2k22n-111 asd2122n-111 asd21l22n-111 asd21k22n-111 asd2222n-111 asd22l22n-111 asd22k22n-111 non-illuminated 3-position selector switches style part number contact mounting operator position maintained spring return from right spring return from left spring return two-way l c r l c r l c r l c r l c r 2no 1 2 x o o o o x knob lever key asd320n asd3l20n asd3k20n asd3120n asd31l20n asd31k20n asd3220n asd32l20n asd32k20n asd3320n asd33l20n asd33k20n 2nc 1 2 o x x x x o knob lever key asd302n asd3l02n asd3k02n asd3102n asd31l02n asd31k02n asd3202n asd32l02n asd32k02n asd3302n asd33l02n asd33k02n 2no 2nc 1 2 3 4 x o o x o o x x o x x o knob lever key asd322n asd3l22n asd3k22n asd3122n asd31l22n asd31k22n asd3222n asd32l22n asd32k22n asd3322n asd33l22n asd33k22n 2no 2nc 1 2 3 4 x x o o o x x o x o o x knob lever key asd322n-309 asd3l22n-309 asd3k22n-309 asd3122n-309 asd31l22n-309 asd31k22n-309 asd3222n-309 asd32l22n-309 asd32k22n-309 asd3322n-309 asd33l22n-309 asd33k22n-309 2no 2nc 1 2 3 4 o o o o x o x o o x o x knob lever key asd322n-310 asd3l22n-310 asd3k22n-310 asd3122n-310 asd31l22n-310 asd31k22n-310 asd3222n-310 asd32l22n-310 asd32k22n-310 asd3322n-310 asd33l22n-310 asd33k22n-310 4no 1 2 3 4 x o x o o o o o o x o x knob lever key asd340n asd3l40n asd3k40n asd3140n asd31l40n asd31k40n asd3240n asd32l40n asd32k40n asd3340n asd33l40n asd33k40n 4nc 1 2 3 4 o x o x x x x x x o x o knob lever key asd304n asd3l04n asd3k04n asd3104n asd31l04n asd31k04n asd3204n asd32l04n asd32k04n asd3304n asd33l04n asd33k04n switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
675 ?30mm - twtd series non-illuminated selector switches (sub-assembled) contact blocks + operator + knob or lever* + color insert* = complete part ? 1. *not needed with key type switches. 2. ? knob type shown. operators style position description part number knob/lever 2 maintained asd200 spring return from right asd2100 spring return from left asd2200 3 maintained, cam 1 maintained, cam 2 asd300-1 asd300-2 spring return from right, cam 1 spring return from right, cam 2 asd3100-1 asd3100-2 spring return from left, cam 1 spring return from left, cam 2 asd3200-1 asd3200-2 spring return from left/right, cam 1 spring return from left/right, cam 2 asd3300-1 asd3300-2 key 2 maintained asd2k00-ra spring return from right asd21k00-rl spring return from left asd22k00 3 maintained, cam 1 maintained, cam 2 asd3k00-1 asd3k00-2 spring return from right, cam 1 spring return from right, cam 2 asd31k00-1-rlc asd31k00-2-rlc spring return from left, cam 1 spring return from left, cam 2 asd32k00-1-rrc asd32k00-2-rrc spring return from left/right, cam 1 spring return from left/right, cam 2 asd33k00-1-rc asd33k00-2-rc 1. order knobs, levers, color inserts separately (see below). 2. for key switches, keys are removable in all maintained positions. other options available, contact idec for details. 3. see page 681 operator t ruth tables for details of difference between cams. j color codes knob/lever color code black b blue s green g red r yellow y white w 1. knob/lever not available in white. 2. color inserts not available in black. 3. lever not available in yellow . handles and inserts style part number knob asdhhy- j lever asdhhl-j* color insert tw-hc1- j 1. in place of j, specify the color code. *not available in yellow. contact blocks style part number 1no 1nc all control units bst-010 bst-010s (early make) bst-001 bst-001s (late break) dummy block bst-d 1. dummy blocks (no contacts) are used with an odd number of contact blocks. 2. combining bst -010s and bst-001s result in overlapping contacts (remain on, or closed, when switch is moved between two positions). switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 676 illuminated selector switches (assembled) assembled illuminated selector switches a sl d 2 (2) 99 11 d n C 111 C r C 24 function sl: illuminated selector switch series designation d: twtd series number of positions 2: 2-position 3: 3-position spring return action blank: maintained 1: spring return from right 2: spring return from left 3: two-way spring return from left and right rated operational voltage (primary) transformer type 126: 120v ac 246: 240v ac 486: 480v ac full voltage type 99: full voltage contact arrangement code 20: 2no 02: 2nc 40: 4no 04: 4nc 11: 1no-1nc 22: 2no-2nc lamp voltage (full voltage units only) 6v : 6v ac/dc 12v : 12v ac/dc 24v : 24v ac/dc 120v: 120v ac 240v : 240v ac (led only) lens color code a: amber g: green r: red s: blue w: white y: yellow circuit code number see circuit # column of selec- tor switch contact arrangement charts on page 679. lamp type blank: incandescent lamp d: led lamp use only when interpreting part numbers. do not use for developing part numbers. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
677 ?30mm - twtd series illuminated selector switches (assembled) illuminated 2-position selector switches k led/lens color codes color code amber a green g red r blue s white w yellow y l full voltage codes voltage code 6v ac/dc 6v 12v ac/dc 12v 24v ac/dc 24v 120v ac 120v 240v ac 240v (led only) style part number contact mounting operator position lamp circuit type maintained spring return from right spring return from left l r l r l r l r 1no 1nc 1 2 o x x o transformer full voltage asld2 m11nn-k asld29911nn-k-l asld21 m11nn-k asld219911nn-k-l asld22 m11nn-k asld229911nn-k-l 2no 1 2 o o x x transformer full voltage asld2 m20nn-k asld29920nn-k-l asld21 m20nn-k asld219920nn-k-l asld22 m20nn-k asld229920nn-k-l 2nc 1 2 x x o o transformer full voltage asld2 m02nn-104-k asld29902nn-104-k-l asld21 m02nn-104-k asld219902nn-104-k-l asld22 m02nn-104-k asld229902nn-104-k-l 2no 2nc 1 2 3 4 o x o x x o x o transformer full voltage asld2 m22nn-k asld29922nn-k- l asld21 m22nn-k asld219922nn-k-l asld22 m22nn-k asld229922nn-k-l 2no 2nc 1 2 3 4 o o x x x x o o transformer full voltage asld2 m22nn-111-k asld29922nn-111-k-l asld21 m22nn-111-k asld219922nn-111-k-l asld22 m22nn-111-k asld229922nn-111-k-l illuminated 3-position selector switches, maintained and spring return style part number contact mounting operator position lamp circuit type maintained spring return from right spring return from left spring return two-way l c r l c r l c r l c r l c r 2no 1 2 x o o o o x transformer full voltage asld3 m 20nn-k asld39920nn-k-l asld31 m 20nn-k asld319920nn-k- l asld32 m 20nn-k asld329920nn-k-l asld33 m 20nn-k asld339920nn-k-l 2nc 1 2 o x x x x o transformer full voltage asld3 m 02nn-k asld39902nn-k-l asld31 m 02nn-k asld319902nn-k-l asld32 m 02nn-k asld329902nn-k-l asld33 m 02nn-k asld339902nn-k-l 2no 2nc 1 2 3 4 x o o x o o x x o x x o transformer full voltage asld3 m 22nn-k asld39922nn-k-l asld31 m 22nn-k asld319922nn-k-l asld32 m 22nn-k asld329922nn-k-l asld33 m 22nn-k asld339922nn-k-l 2no 2nc 1 2 3 4 x x o o o x x o x o o x transformer full voltage asld3 m 22nn-309-k asld39922nn-309-k-l asld31 m 22nn-309-k asld319922nn-309-k-l asld32 m 22nn-309-k asld329922nn-309-k-l asld33 m 22nn-309-k asld339922nn-309-k-l 2no 2nc 1 2 3 4 o o o o x o x o o x o x transformer full voltage asld3 m 22nn-310-k asld39922nn-310-k-l asld31 m 22nn-310-k asld319922nn-310-k-l asld32 m 22nn-310-k asld329922nn-310-k-l asld33 m 22nn-310-k asld339922nn-310-k-l 4no 1 2 3 4 x o x o o o o o o x o x transformer full voltage asld3 m 40nn-k asld39940nn-k-l asld31 m 40nn-k asld319940nn-k-l asld32 m 40nn-k asld329940nn-k-l asld33 m 40nn-k asld339940nn-k-l 4nc 1 2 3 4 o x o x x x x x x o x o transformer full voltage asld3 m 04nn-k asld39904nn-k-l asld31 m 04nn-k asld319904nn-k-l asld32 m 04nn-k asld329904nn-k-l asld33 m 04nn-k asld339904nn-k-l 1. in place of k, specify the lens/led color code, in place of l , specify the full voltage (lamp voltage) code, in place of m , specify the transformer voltage code and in place of n specify the lamp type code. 2. the truth table indicates the operating position of contact block when the operator is switched to that position. x = on (closed contacts) o = off (open contacts) x x = overlapping contacts: remain on (closed contacts) when switch is moved between these positions 3. yellow selector switch comes with white led. m transformer voltage codes voltage code 120vac 240vac 480vac 126 246 486 t ransformers step down to 6v (use 6v lamp). light is independent of switch position. n lamp type codes lamp code incandescent blank led d switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 678 illuminated selector switches (sub-assembled) transformer* + contact block + operator + lamp + lens = complete part *not required for full voltage units (use apd-f full voltage clips instead). operators style position description part number operator 2 maintained asld200 3 maintained, cam 1 maintained, cam 2 asld300-1 asld300-2 2 spring return from right asld2100 spring return from left asld2200 3 spring return from right, cam 1 spring return from right, cam 2 asld3100-1 asld3100-2 spring return from left, cam 1 spring return from left, cam 2 asld3200-1 asld3200-2 spring return from left/right, cam 1 spring return from left/right, cam 2 asld3300-1 asld3300-2 lenses style part number knob aslnhu-j lamps style voltage part number led 6v ac/dc lstd-6k 12v ac/dc lstd-1k 24v ac/dc lstd-2k 120v ac lstd-h2k 240v ac lstd-m4k incandescent 6v ac/dc is-6 12v ac/dc is-12 24v ac/dc is-24 120v ac l-120l 1. in place of k, specify the led color code. 2. the led contains a current-limiting resistor and a protection diode. contact blocks style part number 1no 1nc all control units bst-010 bst-010s (early make) bst-001 bst-001s (late break) dummy block bst-d 1. dummy blocks (no contacts) are used with an odd number of contact blocks. 2. combining bst -010s and bst-001s result in overlapping contacts (remain on, or closed, when switch is moved between two positions). full voltage clips style part number full voltage clips (2 required for each unit) apd-f required for all full voltage models. transformers style primary voltage (50/60hz) part number transformers 120v ac twd-0126 240v ac twd-0246 480v ac twd-0486 6v secondary voltage. k led/lens color codes color code color code amber a blue s green g white w red r yellow y y ellow lens only. yellow led not available, use white led. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
679 ?30mm - twtd series contact arrangement charts how to read contact arrangement charts to determine contact block mounting position, frst make sure the selector switch is oriented as shown on the right contact arrangement type and quantity of switch contacts circuit number * n/d = no designation contact block mounting position position or mounting contact blocks on operator operator position truth table indicates the operating posi- tion of contact block when operator is switched to that position. x = on (closed contacts) o = off (open contacts) x x = overlapping contacts: remain on (closed) when switch is moved between these two positions contact block part number part number to use when ordering sub-assembly contact blocks, as required for use with corresponding mounting position contact arrangement chart: 2-position selector switches style mounting position operator position contact block part number description operator part number contact circuit number maintained spring return from right spring return from left l r l r l r l r 1no n/d 1 o x bst-010 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o o bst-d 1nc 116 1 x o bst-001 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o o bst-d 1no 1nc n/d 1 o x bst-010 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 x o bst-001 103 1 x o bst-001 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o x bst-010 1no-em 1nc-lb 600 1 o x bst-010s knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 x o bst-001s 601 1 x o bst-001s knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o x bst-010s 2no n/d 1 o x bst-010 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o x bst-010 2nc 104 1 x o bst-001 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 x o bst-001 2no 2nc n/d 1 o x bst-010 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 x o bst-001 3 o x bst-010 4 x o bst-001 110 1 x o bst-001 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o x bst-010 3 x o bst-001 4 o x bst-010 111 1 o x bst-010 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o x bst-010 3 x o bst-001 4 x o bst-001 4no n/d 1 o x bst-010 knob/lever key illuminated knob asd200 asd2k00 asld200 asd2100 asd21k00 asld2100 asd2200 asd22k00 asld2200 2 o x bst-010 3 o x bst-010 4 o x bst-010 switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 680 contact arrangement chart: 3-position selector switches style mounting position operator position contact block part number description operator part number contact circuit number maintained spring return from right spring return from left two-way l c r l c r l c r l c r l c r 1no 1nc 202 1 x o o bst-010 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 x x o bst-001 203 1 o x x bst-001 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 o o x bst-010 302 1 x o x bst-010 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 x x o bst-001 303 1 o x o bst-001 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 o o x bst-010 2no n/d 1 x o o bst-010 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 o o x bst-010 301 1 x o x bst-010 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 o o x bst-010 2nc 304 1 o x o bst-001 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 x x o bst-001 n/d 1 o x x bst-001 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 x x o bst-001 2no 2nc n/d 1 x o o bst-010 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 o o x bst-010 3 o x x bst-001 4 x x o bst-001 210 1 o x x bst-001 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 o o x bst-010 3 o x x bst-001 4 o o x bst-010 308 1 x o x bst-010 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 x x o bst-001 3 x o x bst-010 4 x x o bst-001 309 1 x o x bst-010 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 x x o bst-001 3 o x o bst-001 4 o o x bst-010 310 1 o x o bst-001 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 o o x bst-010 3 o x o bst-001 4 o o x bst-010 1. each operator sub-assembly is available as a -1 and a -2 for 3-position selector switches. the internal cam of a -1 is different from that of a -2. this results in designated combinations of open and closed contacts in the various operator positions. 2. n/d = no circuit number designation required in assembled part number . 3. x = on (closed contacts) o = off (open contacts). x x overlapping contacts remain on (closed) when switch is moved between these two positions. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
681 ?30mm - twtd series contact arrangement chart: 3-position selector switches style mounting position operator position contact block part number description operator part number contact circuit number maintained spring return from right spring return from left two-way l c r l c r l c r l c r l c r 4no n/d 1 x o o bst-010 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 o o x bst-010 3 x o o bst-010 4 o o x bst-010 305 1 x o x bst-010 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 o o x bst-010 3 x o x bst-010 4 o o x bst-010 4nc n/d 1 o x x bst-001 knob/lever key illuminated knob asd300-1 asd3k00-1 asld300-1 asd3100-1 asd31k00-1 asld3100-1 asd3200-1 asd32k00-1 asld3200-1 asd3300-1 asd33k00-1 asld3300-1 2 x x o bst-001 3 o x x bst-001 4 x x o bst-001 314 1 o x o bst-001 knob/lever key illuminated knob asd300-2 asd3k00-2 asld300-2 asd3100-2 asd31k00-2 asld3100-2 asd3200-2 asd32k00-2 asld3200-2 asd3300-2 asd33k00-2 asld3300-2 2 x x o bst-001 3 o x o bst-001 4 x x o bst-001 1. each operator sub-assembly is available as a -1 and a -2 for 3-position selector switches. the internal cam of a -1 is different from that of a -2. this results in designated combinations of open and closed contacts in the various operator positions. 2. n/d = no circuit number designation required in assembled part number . 3. x = on (closed contacts) o = off (open contacts). x x overlapping contacts remain on (closed) when switch is moved between these two positions. operator truth tables use the following tables to build custom selector switches. 2 position selector switches contact mounting position operator position left right asd200 bst-010 (no) l o x r o x bst-001 (nc) l x o r x o bst-010s (no-em) l o x r o x bst-001s (nc-lb) l x o r x o 3 position push/pull switches contact operator position pull normal push ayld22 bst-010 (no) o o x bst-001 (nc) x o o bst-010s (no-em) o x x bst-001s (nc-lb) x x o 3 position selector switches contact mounting position operator position left center right asd300-1 asld300-1 asd3k00-1 bst-010 (no) l x o o r o o x bst-001 (nc) l o x x r x x o bst-010s (no-em) l x o o r o o x bst-001s (nc-lb) l o x x r x x o contact mounting position operator position left center right asd300-2 asld300-2 asd3k00-2 bst-010 (no) l x o x r o o x bst-001 (nc) l o x o r x x o bst-010s (no-em) l x o x r o o x bst-001s (nc-lb) l o x o r x x o switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 682 accessories twtd series twtd series accessories item appearance description/usage part number lamp removal tool rubber tool used to install or remove leds and incandescent lamps or-55 metal bezel replacement locking ring/ bezel standard octagonal units (chrome-pl.). og-81 extended, non-illuminated (chrome-pl.). og-82 extended, illuminated (chrome-pl.). og-83l jumbo mushroom shallow shroud abn4g jumbo mushroom deep shroud abn4f plastic bezel black plastic locking ring/bezel ogp11b boot/cover used to cover and protect pushbuttons in place of j, specify neoprene rubber boot color: b (black), g (green), r (red), y (yellow) oc-11 j flush units (clear plastic -40? to +60?c). oc-121 extended units (clear plastic -40? to +60?c). oc-122 anti-rotation ring plastic washer for nameplates or panels that should not be scratched. ogl-d1t thrust washer/anti-rotation ring for use with notched panel cutout. ogl-d1s mounting hole plug plugs used to fll unused 30mm panel cutouts. plastic with locking nut attached. obp-11 metal with locking nut attached ob-11 grey rubber (-5? to +60?c) ob-13 terminal tab adaptor tab #250 17/64 x 3/64 (6.35mm x 0.8mm): single tab tw-fa1 full voltage adaptor used on all full voltage illuminated units. two required per unit. (m3.5 screw and saddle) apd-f lock out adaptor used to provide lockout protection for twtd pushbuttons and knob selectors. ? 1-13/64 (30mm) ol-kl1 replacement keys pair of keys (#0) tw-sk switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
683 ?30mm - twtd series fingersafe covers for twtd series item description used with part number fingersafe terminal cover, for full voltage pilot lights, adds 3mm to overall depth apd199... full voltage pilot lights apd-pvl fingersafe terminal cover, for contact blocks, adds 3mm to overall depth non-illuminated pushbuttons abd..., and aod... n-vl2 fingersafe terminal cover, adds 1.5mm to overall depth transformer pilot lights and illuminated units n-vl3 fingersafe terminal cover, adds 4 mm to depth full voltage illuminated pushbuttons n-vl4 dimensions on page 687. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 684 nameplates twtd series faceplates nald nakd naqd hnav dimensions 1.85" (47.5mm) ?1.19" (30.5mm) 1.56" (40mm) 2.24" (57.5mm) ?1.19" (30.5mm) 2.03" (52mm) 1.95" (50mm) ?1.19" (30.5mm) 1.95" (50mm) 5mm ?60mm 30.5mm description part number nameplate (blank) nald-b (black) nald-r (red) nakd-b (black) nakd-r (red) naqd-b (black) naqd-r (red) hnav-o nameplate (engraved) nald-j nakd-j naqd-j hnav-27 emergency stop 1. nameplates are made of 0.031 aluminum. lettering is white letters engraved on black backgroun d. 2. in place of j , insert either the standard legend code from table below or custom engraving delimited by . 3. hna v available in yellow only. standard legend codes pushbuttons pushbuttons/selector switches selector switches legend code legend code legend code legend code legend code auto close down emerg.stop* fast forward hand high in inch jog low lower off on 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 open out raise reset reverse run slow start stop* stop test up i (intl on) o (intl off) emo 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 auto-man close-open down-up fast-slow for-rev hand-auto high-low jog-run left-right lower-raise man-auto off-on on-off open-close raise-lower 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 rev-for run-jog run-safe safe-run slow-fast start-stop stop-start up-down 216 217 218 219 220 221 222 223 auto-man-off auto-off-man close-off-open down-off-slow fast-off-slow for-off-rev left-off-right lower-off-raise off-man-auto off-slow-fast off-1-2 open-off-close slow-off-fast summer-off-winter up-off-down 1-off-2 hand-off-auto 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. *available in red as standard legend code 104 and 124. to order engraved nameplate and codes, add legend code to nameplate part number. character height based on the number of characters, space and size of nameplate. standard character size is 3/16. 2. nameplates with standard legends are the same list price as blank nameplates. special engravings , additional cost. to specify engraving instructions, use the nameplate order form on next page. switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
685 ?30mm - twtd series custom engraved nameplates order form twtd series copy this order form and use it to specify letter height, custom engravings, location of engraving on nameplate, and quantity desired. to ensure engraving accuracy, fax it to your idec representative. or distributor. y our company name: _________________________________________ y our name: _________________________________________ telephone: _________________________________________ fax & email: _________________________________________ idec rep/distributor contact: _________________________________ po number (if known): _________________________________ idec rep/distributor phone: _________________________________ idec rep/distributor fax & email: _________________________________ nald nameplate engraving location step 1. choose letter size - 7/64 or 1/8. check the box for the letter size you want. then write your lettering in box below checkboxes. note: 1/8 size let- ters cannot exceed 13 characters. step 2. specify quantity. qty enter the number of nameplates desired in the box on the right. sample letter sizes 7/64 letters: 1/8 letters: 7/64 letter size 11 characters max (for 7/64 size letters) 1/8 letter size 9 characters max (for 1/8 size letters) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 nakd nameplate engraving location step 1. choose letter size - 7/64 or 1/8. check the box for the letter size you want. then write your lettering in box below checkboxes. note: 1/8 size letters cannot exceed 9 characters. step 2. specify quantity. qty enter the number of nameplates desired in the box on the right. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 sample letter sizes 1/8 letters: naqd nameplate engraving location step 1. choose letter size - 7/64 or 1/8. check the box for the letter size you want. then write your lettering in box below checkboxes. note: 1/8 size letters cannot exceed 16 characters. 7/64 letter size 20 characters max (for 7/64 size letters) 1/8 letter size 16 characters max (for 1/8 size letters) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 step 2. specify quantity. qty enter the number of nameplates desired in the box on the right. sample letter sizes 3/32 letters: 1/8 letters: switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 686 switch engraving order form C twtd series copy this order form and use it to specify letter height, maximum number of lines and text to be engraved. to insure engraving accuracy, fax it to your idec representative or distributor. your company: telephone: name: fax: address: email: po: part number to be engraved: please check one of the boxes below to indicate your choice of engraving optio ns: square switch 65mm jumbo mushroom ?29mm, ?40mm mushroom head engraving area 1 engraving area 2 ? # of lines letter height max. characters per line # of lines letter height max. characters per line # of lines letter height max. characters per line 1 5/32 7 1 3/4 4 engraving area 1 1 5/32 5 1/8 8 5/16 5 1/8 5 2 5/32 7 2 5/16 5 engraving area 2 1 5/32 7 1/8 8 1/4 6 1/8 7 3 1/8 8 5/32 8 1. above mentioned specifcations hold true for standard size push- buttons (round and square). 2. ? engraving area 2 can be engraved for 40mm mushroom head non-illuminated pushbutton only. 3. engraving is done on the button itself for non-illuminated push but- tons and on marking plate for illuminated push buttons and pilot lights. 4. please enter text exactly how you want it engraved, take care to emphasize capital or small letters. 4 custom* 3 5/32 8 *engraving is possible, but character size will be smaller than standard sizes. 1/8 9 round switch 4 1/8 9 # of lines letter height max. characters per line enter text to be engraved: line 1: line 2: line 3: line 4: sample letter sizes 1/8 letters: 5/32 letters: all engraving is 5/8mm wide. 1 5/32 7 1/8 8 2 5/32 7 1/8 8 3 1/8 8 4 custom* *engraving is possible, but character size will be smaller than standard sizes. for idec internal use only: work order #: switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
687 ?30mm - twtd series dimensions (mm) pushbutton 5.5 23 9 panel thickness 0.8 to 7.5 ?35 40 ?25 ?40 14.5 53 ( 1 or 2 blocks) 76 ( 3 or 4 blocks ) m3.5 terminal screw pushbuttons dimension a dimension b flush extended extended w/full shroud 0.351 (9mm) 0.566 (14.5mm) 0.663 (17mm) ? 0.975 (25mm) ? 0.975(25mm) ? 1.11 (28.5mm) mushroom mushroom w/full shroud jumbo mushroom ? 1.56 (40mm) 0.858 (22mm) 0.936 (24mm) 1.13 (29mm) ? 1.56 (40mm) ? 1.87 (48mm) ? 2.54 (65mm) mushroom, pushlock turn reset and push-pull ? 1.56 (40mm) *0.975 (25mm) **0.975 (25mm) ? 1.56 (40mm) ? 1.56 (40mm) *dimension when operator is in reset position. **dimension when operator is in pull position. mushroom pushbutton w/full shroud m3.5 terminal screw 5.5 23 40 ?40 53 ( 1 or 2 blocks) 76 ( 3 or 4 blocks ) 22 ?40 panel thickness 0.8 to 7.5 illuminated pushbuttons w/transformer m3.5 terminal screw ?35 9 97.5 (2 blocks) 120.5 (4 blocks) a panel thickness 0.8 to 7.5 40 ?40 m3 terminal screw b full voltage 63 ( 2 blocks ) m3 terminal screw ?24 ?35 23 86 ( 4 blocks ) 9 24 5.5 panel thickness 0.8 to 7.5 m3.5 terminal screw 40 ?40 illuminated pushbuttons dimension a dimension b flush w/full shroud 0.975 (25mm) 0.995 (25.5mm) ? 0.936 (24mm) ? 0.936 (24mm) extended w/full shroud 0.741 (19mm) 0.761 (19.5mm) ? 0.936 (24mm) ? 0.936 (24mm) ? 1.56 (40mm) mushroom pushlock turn reset, push-pull *0.975 (25mm) **0.975 (25mm) ? 1.56 (40mm) ? 1.56 (40mm) *dimension when operator is in reset position. **dimension when operator is in pull position. pilot lights a:29.59 b:64.52 2 40 ?25 ?35 ?40 m3.5 terminal screw m3.5 terminal screw panel thickness: 0.8 to 7.5 mm selector switches knob lever key m3.5 terminal screw 40 5.5 23 ?35 53 ( 1 or 2 blocks ) 76 ( 4 blocks) 21 ?40 90 45 45 panel thickness 0.8 to 7.5 m3.5 terminal screw 40 5.5 23 ?35 53 ( 1 or 2 blocks ) 76 ( 4 blocks ) 21.5 ?40 90 45 45 panel thickness 0.8 to 7.5 m3.5 terminal screw 40 5.5 23 ?35 53 ( 1 or 2 blocks ) 76 ( 4 blocks ) ?40 9 16.5 38 90 45 45 panel thickness 0.8 to 7.5 illuminated knob 40 ?40 23 5.5 28 9 ?35 ?25 m3.5 terminal screws m3 terminal screw 63 ( 2 blocks ) a: 86 ( 4 blocks ) b: 97.5 ( 2 blocks ), 120.5 ( 4 blocks ) panel thickness 0.8 to 7.5 ( including nameplate) 90 45 45 switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices
?30mm - twtd series 688 selector switches panel cut-out ? 0.195" (5mm) ? 1.20" (30.5mm) > 1.95" (50mm)* 1.64" (42mm) 1. *jumbo mushroom < 2.61 (66mm) 2. minimum mounting centers are applicable to switches with one stack of contact blocks. when mounting two stacks of contact blocks, minimum centers should allow for access to wiring. 3. the ? 0.195 (? 5mm) recess is necessary when either the nameplate or anti-rotation ring is used. illuminatedselector switches ol-kl1 lock-out adaptor oc-31 pushbutton clear boot ogl-31 anti-rotation ring ob-31 mounting hole rubber plug waterproof rubber gasket 0.5t 24 key hole ?8 30 70 ?50 ?30.2 93 29.5 30 r66.5 panel thickness 0.8 to 3.2 82.5 22 ( oc-32 ) 18 ( oc-31 ) ?32.6 ?22 ?27.4 10.2 0.8 ?29 ?25 3.5 3.5 finger-safe cover n-vl2 n-vl3 n-vl4 apd-pvl switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers switches & pilot devices www.idec.com
689 ?30mm - twtd series operating instructions adjustment for panel thickness each unit is shipped with several waterproof gaskets which are 0.06 (1.5mm) and 0.12 (3mm) thick. combine the gaskets for a dimension approximately equal to panel thickness and install between the bezel and the body of the unit. a trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. when using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below. selector switches the operator shaft of each unit has a recess to identify in which direction to install the handle. align the handle with the recess. press color insert (tw-hc1) into the standard operating positions. standard operation positions 2-position, 90 3-position, 45 1 2 1 2 0 non-illuminated 3-position operators 12 0 1 2 0 1 2 0 installation of twtd series units twtd pilot lights twtd illuminated pushbuttons twtd selector switches (transformer or full voltage) terminal x1 = positive terminal x2 = negative installation of led illuminated units transformer units are recommended for use in areas subjected to inductive noise. when using full voltage types, install a protection diode as shown below. use diode with dc power supply to protect against surges and noise. make sure that led illuminated units are installed with correct polarity , as indicated at the terminals. application example for push-to-test pilot light a typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to check the lamp/led circuit. transformer/ac-adapter circuit full voltage circuit switches & pilot devices signaling lights relays & sockets timers contactors terminal blocks circuit breakers 800-262-idec (4332) ? usa & canada switches & pilot devices